Multifunction impulse switching relay UC. 1 NO contact potential-free 10A/250V AC - ESR61NP-UC

Item number: ESR61NP-UC

Category: Impulse relay


28,25 €

including 19% VAT. , (Standard)

In stock!

Shipping time: 2 - 5 workdays

piece


Description

Multifunction impulse switching relay UC. 1 NO contact potential-free 10A/250V AC - ESR61NP-UC
1 NO contact not potential-free 10 A/250 V AC, 230 V LED lamps up to 600 W, incandescent lamps 2000 W. Off-delay with switch-off early warning and button permanent light can be switched on. Standby loss only 0.7 watts. For flush mounting. 45mm long, 45mm wide, 18mm deep. Contact switching in the zero crossing to protect the contacts and lamps. The latest hybrid technology combines the advantages of wear-free electronic control with the high performance of special relays. Due to the use of a bistable relay, there is no coil power loss and no heating as a result, even when switched on. After installation, wait for the brief automatic synchronization before the switched load is connected to the mains. Control voltage 230 V, additionally with electrically isolated universal control voltage 8..230 V UC. Supply and switching voltage 230 V. Very low switching noise. Time setting up to 120 minutes in ESV function. Buttons with a glow lamp current of up to 50 mA can be connected to the control input. If the supply voltage fails, it is switched off in a defined manner. If the delay time is set to a minimum in the ESV function, the release delay is switched off and the normal ES impulse switch function results. Can be switched to the ER switching relay function. No glow lamp current is permitted in the ER function and only control input A1-A2 should be used. Also suitable for feedback with the switching voltage of a dimmer switch in the ER function. When the switch-off pre-warning is switched on, the lighting flickers approx. 30 seconds before the time expires and a total of 3 times at increasingly shorter time intervals. When the button permanent light is switched on, the light can be set to permanent by pressing buttons longer than 1 second, which is automatically switched off after 2 hours or can be switched off by pressing buttons longer than 2 seconds. If the switch-off pre-warning and the button permanent light are switched on, the switch-off pre-warning is given after the permanent light has been switched off.

Specifications

  • Control voltages 230V and 8..230V UC
  • Rated switching capacity 10A/250V AC
  • Incandescent and 2000W
  • Halogen lamp load1) 230V
  • Fluorescent lamps with KVG 1000VA
  • in DUO circuit or
  • uncompensated
  • Fluorescent lamps with KVG 500VA
  • parallel compensated or with ECG
  • Compact fluorescent lamps with 15x7W
  • ECG and energy-saving lamps 10x20W
  • Control button 230 V with
  • Glow lamp current up to 50mA
  • Lamp connector
  • A1-A2 universal control voltage
  • 8..230V UC
  • Standby loss (effective power) 0.7W 1) For lamps with max. 150W.

Product Tags