Relais 48VDC bistabil - ST1-L2-DC48V SDS
Beschreibung
Relais 48VDC bistabil - ST1-L2-DC48V SDS
| Operating function | 2 coil latching |
| [[Coil data]]Rated coil voltage | 48V DC |
| [[Specifications]]Contact arrangement | 1 Form A 1 Form B |
| Protective construction | Sealed |
| Terminal shape | PC board terminal |
| Accessories | Sockets are available. |
| Standard packing Carton (pieces) |
50 |
| Standard packing Case (pieces) |
500 |
| [[Coil data]]Set voltage (at20°C 68°F) | Max. 80% V of Rated coil voltage (initial) |
| [[Coil data]]Reset voltage (at20°C 68°F) | Max. 80% V of Rated coil voltage (initial) |
| [[Coil data]]Rated operating current [±10%] (at 20°C) | Set coil: 4.7 mA Reset coil: 4.7 mA |
| [[Coil data]]Coil resistance [±10%] (at 20°C) | Set coil: 10,200 O Reset coil: 10,200 O |
| [[Coil data]]Rated operating power | Approx. 240 mW |
| [[Coil data]]Max. allowable voltage (at 20°C 68°F) | 150% V of Rated coil voltage |
| [[Specifications]]Contact shape | Single |
| [[Specifications]]Contact resistance (initial) | Max. 30 mO (by voltage drop 6 V DC 1 A) |
| [[Specifications]]Contact material | Au-flashed AgSnO2 type |
| [[Specifications]]Contact rating (resistive load) | 8 A 250 V AC, 5 A 30 V DC |
| [[Specifications]]Max. switching power (resistive load) | 2,000 VA, 150 W |
| [[Specifications]]Max. switching voltage | 250 V AC, 30 V DC |
| [[Specifications]]Max. switching current | 8 A (AC), 5 A (DC) |
| [[Specifications]]Min. switching load (reference value) | 100 mA 5 V DC |
| [[Specifications]]Insulation resistance (initial) | Min. 1,000 MO (At 500 V DC, Measured portion is the same as the case of dielectric strength.) |
| [[Specifications]]Dielectric strength (initial) : Between open contacts | 1,200 Vrms for 1 min. (detection current: 10 mA) |
| [[Specifications]]Dielectric strength (Initial) : Between contact sets | 2,000 Vrms for 1 min. (detection current: 10 mA) |
| [[Specifications]]Dielectric strength (initial) : Between contact and coil | 3,750 Vrms for 1 min. (detection current: 10 mA) |
| [[Specifications]]Surge withstand voltage (initial) : Between contact and coil | 6,000 V |
| [[Specifications]]Set time (Initial) (at 20°C 68°F) (Initial) | Max. 15 ms (at rated coil voltage, without bounce) |
| [[Specifications]]Reset time (Initial) (at20°C 68°F) | Max. 15 ms (at rated coil voltage, without bounce, without diode) |
| [[Specifications]]Shock resistance (Functional) | Min. 196 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs) |
| [[Specifications]]Shock resistance (Destructive) | Min. 980 m/s2 (half-sine shock pulse: 6 ms) |
| [[Specifications]]Vibration resistance (Functional) | 10 to 55 Hz (at double amplitude of 2.0 mm, detection time: 10 µs) |
| [[Specifications]]Vibration resistance (Destructive) | 10 to 55 Hz (at double amplitude of 3.0 mm) |
| [[Specifications]]Mechanical life | Min. 1x107 ope. (at 180 times/min.) |
| [[Specifications]]Conditions | Ambient temperature: ?40 to +60°C, Humidity: 5 to 85% R.H. (Avoid icing when using at temperatures lower than 0°.) |
| [[Specifications]]Unit weight | Approx. 10 g |
| [[Electrical life]]Resistive load | Min. 100,000 ope. 8 A 250 V AC (ON : OFF = 1 s : 5 s) |